OpenPlant Modeler Help

HVAC Equipment Gallery

Used to place HVAC Equipment components.

Accessed from the HVAC ribbon:

The following gallery displays which can be left floating or docked to the drawing area.

The following table shows the component options in the gallery along with the key in syntax. Selecting a tool from one of the placement galleries activates the Place Component dialog. The generic placement settings, along with the unique set of dimensional and data properties provide the core workflow used to accurately position equipment components in the model.

Component <Component Class> in Placement Key In syntax (Mechaddin Place <Component Class> dsc=HVAC)
Single Inlet Variable Air Volume Device SINGLE_INLET_VARIABLE_AIR_VOLUME_DEVICE
Dual Inlet Variable Air Volume Device DUAL_INLET_VARIABLE_AIR_VOLUME_DEVICE
Fan Power Unit FAN_POWER_UNIT
Axial Fan HVAC_AXIAL_FAN
Radial Fan HVAC_RADIAL_FAN
Centrifugal Inline Round Fan CENTRIFUGAL_INLINE_ROUND_FAN
Air Filter AIR_FILTER
Duct Cooler HVAC_DUCT_COOLER
Duct Heater HVAC_DUCT_HEATER
Duct Humidifier STEAM_HUMIDIFIER

Component Placement

Select an option from the HVAC Equipments gallery.

The Place Component dialog displays. This dialog is common to all HVAC components and allows you define a component's physical parameters as well as general properties before placement. The dialog remains open throughout the placement process.

In the Place Component dialog's Settings tab, select a placement point to determine which port serves as the placement point for the component.
Note: Some components may only have a Main_Port option available.
The HVAC Port Settings tab of the Place Component dialog allows you to define the End Preparations for the ports on the component to be placed. An example is shown below:
End Prep Defines which port to apply the EndPrep Type, Size and Length values to. You are able to define different values for each port if desired.
EndPrep Type HVAC_Flange_End, HVAC_MALE_END, HVAC_Female_End, HVAC_Plain_End
EndPrep Size Enter a size for the EndPrep Type.
Note: This is disabled if HVAC_PLAIN_END is selected.
Endprep Length Enter length for the selected EndPrep Type.
The Design Conditions tab provides fields to define the physical parameters of the component. The field options will vary depending on the type of component being placed.

While enter/changing values in the fields, the component is dynamically updated in the drawing so you can see the changes before placing the component.

An example of the design conditions tab (Single Inlet Variable Air Volume Device) is displayed below:
Once the component parameter and property values are defined you are prompted to select a placement location for the component.

Pick a location and click a data point. If the component requires a direction pick, use the mouse to rotate the component into the correct position then click a data point.

Right-click to complete the process.